De-Rating < | > Selection of the main device | |
![]() |
![]() |
![]() |
Offline Switch Mode AC-DC Power Supplies (entry example) |
Input specificationAC Rated input voltage(AC100V~240V)※Tests to obtain safety standards are performed at the rated voltage. AC input voltage range(AC85V~276V) Rated input frequency (50/60Hz) |
Output specification※Typ current is required for estimated product life calculation.Rated output voltage (12V) Rated output current (1.0A) Rated output power (12W) Output voltage range (12V ±5%) Output current range (min 0.01A / typ 1.0A / max 1.5A) Peak output power (max 18W) |
Efficiency※Target valueEfficiency (typ 85% input AC100V output 12V 1.0A) |
Output noiseOutput ripple noise (200mVp-p max)Output spike noise (400mVp-p max) |
EMC noise [Electro Magnetic Compatibility]※Ask the person in charge of applying for safety standards.Emission noise [Electro Magnetic Interference] ・Conducted emission (CISPR 11/EN 55011 class B) ・Radiated emission (FCC Part15 Subpart B class B) ・Harmonic current emissions (IEC 61000-3-2 class A) Immunity noise [Electro Magnetic Susceptibility] (IEC61000-4) ・Electrostatic discharge (IEC61000-4-2 Level 1) ・Radiated, radio-frequency,electromagnetic field (IEC61000-4-3 Level 1) ・Fast Transient Burst (IEC61000-4-4 Level 1) ・Surge (IEC61000-4-5 Level 1) ・Conducted disturbances, induced by radio-frequency fields (IEC61000-4-6 Level 1) ・Power frequency magnetic field (IEC61000-4-8 Level 1) ・Voltage dips, short interruptions and voltage variations (IEC61000-4-11 class1) |
ProtectionOutput over current protection (1.6A min)Output over voltage protection Thermal Shutdown |
Safety Approval※Ask the person in charge of applying for safety standardsSafety standards (IEC62368-1 class II Double insulation) Minimum creepage distances ・Basic insulation (3.0mm min) ・Reinforced or Double insulation (6.0mm min) Leakage current (0.25mA max AC240V) |
Insulation specification※Ask the person in charge of applying for safety standards.Withstand voltage [HI-POT Test] (3000V 10mA 1min) Insulation resistance (100MΩ DC500V) |
Operating ambient temperatureAverage (40℃)※Average ambient temperature is required for estimated product life calculation. Range (-10℃~60℃) |
OthersStandby power (50mW max)Inrush current (100A max) Estimated product life (10 Years) |
![]() |