Overload protection
Increase the load current until the output voltage drops and check at which
point the overload protection works.
We recommend C.R mode for the electronic load.
If this test breaks the power supply circuit, it is recommended to improve
the circuit design.
[ Improves circuit breakdown in overload protection tests ]
Overvoltage protection
Short-circuit the part circled in red in the circuit diagram below to perform an overvoltage protection test.
The test is performed by shorting the circuit during normal operation with
the rated input/output.
We recommend C.C mode for the electronic load.
If the overvoltage test cannot be performed successfully, reduce the output
current to half of the rated value.
If this test breaks the power supply circuit, it is recommended to improve
the circuit design.
[ Improves circuit breakdown in overvoltage protection tests ]
※Some ICs do not have an output overvoltage protection function.