Top > Technical-notes > VNWA > Convert Inductor's VNWA-s1p data to inductance.

Convert Inductor's VNWA-s1p data to inductance.

Explanation of how to calculate inductance from extracted VNWA s1p data.

Import the VNWA data of the frequency characteristics of the coil into EXCEL.
This is a plot of a 1μH coil on an S11 Smith chart.
Explanation about extracted s1p data.
This is an image of a spreadsheet created to measure the S11 of a 1 μH coil using a Vector Network Analyzer (VNWA3E) DG8SAQ, import the S1p data into Excel, and create a frequency response graph.
Calculates the phase of the reflection coefficient.
This is an image of how to measure the S11 of a 1 μH coil using a Vector Network Analyzer (VNWA3E) DG8SAQ, import the S1p data into Excel, and calculate the phase of the reflection coefficient.
Calculate reactance from phase.
This is an image of how to measure the S11 of a 1 μH coil using a Vector Network Analyzer (VNWA3E) DG8SAQ, import the S1p data into Excel, and calculate the reactance from the phase of the reflection coefficient.
Calculate inductance from reactance.
This is an image of how to measure the S11 of a 1 μH coil using a vector network analyzer (VNWA3E) DG8SAQ, import the S1p data into Excel, and calculate the inductance from the reactance.
※ Angles of trigonometric functions are expressed in radians.
Displays the converted Inductance data as a graph.
Click here to download Create-S11LFgraph-VNWAs1p.xlsx